Guide

Treating PFAS at a California water system: options, permits and sampling

Adding PFAS treatment changes more than the water. The system applies for an amended water supply permit before changing its treatment, may ask its district to approve sampling of the treated water, and can stop the quarterly response-level notice once the PFAS is removed. This guide sets out what the federal rule, California’s regulations, the three general orders and DDW’s FAQ say about each step.

Checked against 40 CFR 141.61, California Code of Regulations, title 22, section 64556, the three general orders, DDW’s PFAS FAQ (August 12, 2026), U.S. EPA’s April 2024 treatment fact sheet and its April 2026 disposal guidance on November 8, 2026. This guide summarizes those sources; it isn’t legal or engineering advice, so confirm your plans with your district office.

PFAS treatment: what each source says
QuestionWhat the sources say
Which technologies remove PFASAnion exchange, granular activated carbon (GAC), reverse osmosis and nanofiltration (40 CFR 141.61(d)); DDW names GAC, membrane separation and ion exchange as the most common (FAQ Q8.1)
Is a permit amendment neededYes: an application for an amended water supply permit goes to the State Water Board before any addition or change in treatment (22 CCR 64556(a)(4))
Which media are allowedAsk the district office for the list of media already permitted (FAQ Q8.2); new media go through an investigatory process (FAQ Q8.3)
Can treated water be sampledYes, in addition to the ordered monitoring, with the district office’s written approval of the sampling location and configuration under GO 2022 and GO 2025, or its input under GO 2024 (GO 2022 Provision 8; GO 2025 Provision 10; GO 2024 Provision 19)
Does the quarterly notice continueNo: quarterly response-level notice isn’t required once treatment removes the PFAS (FAQ Q6.4)

Treatment options

The federal rule lists the same best available technologies for every regulated PFAS and the Hazard Index mixture: anion exchange, GAC, reverse osmosis and nanofiltration (40 CFR 141.61(d), Table 3). DDW’s FAQ names GAC, membrane separation (nanofiltration or reverse osmosis) and ion exchange as the most common processes (Q8.1).

EPA’s April 2024 treatment fact sheet names the same technologies as small system compliance technologies for systems serving 10,000 or fewer people, with affordability depending on size: anion exchange for all small systems, GAC in most cases for systems serving 25 to 500 people and in all cases for larger ones, and reverse osmosis and nanofiltration for systems serving 3,301 to 10,000. It also says EPA hasn’t designated point-of-use or point-of-entry devices as compliance options for the PFAS limits. It advises systems to consult their primacy agency, seek technical assistance and pilot-test alternatives before choosing.

Amend the water supply permit first

California’s regulations require an application for an amended domestic water supply permit before any addition or change in treatment, including its design capacity and process (22 CCR 64556(a)(4)). The same section requires an application before adding a new source, changing a source in a way that could affect the quantity or quality of supply, or changing an existing source’s status, such as from active to standby (64556(a)(3)), and whenever the State Water Board says a change needs one (64556(b)).

DDW keeps a list of media that have already been permitted for PFAS treatment; ask your district office for it (FAQ Q8.2). Approving new media “will require an investigatory process” (Q8.3); ask your district office about that process and whether pilot studies will be needed.

Sampling treated water under the general orders

GO 2022 and GO 2025 let a system that treats for PFAS, for example by blending, GAC, ion exchange or reverse osmosis, also sample the treated or delivered water to determine whether a notification or response level is exceeded. The system first gets the district office’s written approval of the sampling location and configuration (GO 2022 Provision 8; GO 2025 Provision 10). GO 2024 lets a system that treats voluntarily sample the treated or delivered water to determine its notification requirements, and asks it to contact the district office for input on the sampling location and configuration (Provision 19).

Federal samples are taken at each entry point to the distribution system (40 CFR 141.902(a)(1)), and DDW accepts results from either the source or the entry point for both the federal rule and the general orders, once the system tells its district office which location it proposes (FAQ Q1.5). For the federal dates, see The federal PFAS rule for California water systems.

How treatment changes the notices

When PFAS in the water entering the distribution system exceeds a response level, GO 2022 and GO 2025 require the system to take the source out of service immediately or provide public notice under Health and Safety Code section 116378, and to repeat that notice each quarter while the PFAS stays above the response level (Provision 9 of each). GO 2024 lists treatment or blending as a third option (Provision 18). DDW’s FAQ says quarterly notice isn’t required once PFAS is removed from the drinking water, or while the well is out of service (Q6.3 and Q6.4). For what the notices must say and how to deliver them, see PFAS notices in California.

For the Consumer Confidence Report, DDW says a system that treats for PFAS should follow its treatment plant permit conditions, and that the report generally reflects the water entering the distribution system. DDW also recommends giving as much information as possible, describing the system’s efforts to manage water quality, and checking with the local DDW office on what to report (Q6.5); see Reporting PFAS in your Consumer Confidence Report in California.

While treatment is being built

Until treatment is running, the response-level options are to take the source out of service or provide public notice (Health and Safety Code section 116378(c)(3)), with treatment or blending also listed under GO 2024 (Provision 18). For the federal limits, DDW’s FAQ lists adding treatment, removing a source, adding a new source or another alternative (Q7.5). Adding a source, changing one, or changing a source’s status (for example, taking it from active to standby) can require a permit amendment application (22 CCR 64556(a)(3)); coordinate taking a source out of service with your district office.

Spent media and concentrate

EPA’s treatment fact sheet says exhausted GAC can be landfilled, incinerated or reactivated, that spent anion exchange media is usually landfilled or incinerated, and that reverse osmosis and nanofiltration concentrate may be discharged to surface water or a sanitary sewer, or injected into a permitted underground injection well, where permits allow. EPA’s interim guidance on destroying and disposing of PFAS and PFAS-containing materials, updated in April 2026, is non-binding and discusses thermal treatment, landfills and underground injection. Plan for these residuals in the project and in its permits.

For grants and loans that can pay for treatment, see Funding PFAS projects at California water systems.

How Weirline helps

Weirline compares every result with California’s notification and response levels, shows the federal limits beside them, and dates the notices and reports each order requires, so you can see which sources need action first. Your team approves every output.

Ask for this view of your sourcesRequest a demo

Sources

See your own sources on the lists.

Send us your water system’s name or PWS ID. We’ll send back every source the State Water Board’s current lists show for it under GO 2025, GO 2022 and GO 2024, and what each order asks of it next.